Skip to Store Area:

 

http://nadascientific.com/media/catalog/product/cache/11/image/9df78eab33525d08d6e5fb8d27136e95/n/6/n600-ha151b-potentiostat-galvanostat-image04.jpg

Full Size
No
PDF Downloads Product Sheet for Compact Potentiostat/Galvanostat

Manual for Compact Potentiostat/Galvanostat
Name Potentiostat/ Galvanostat, Compact
Dimensions No
Maximum Output Voltage 15V
Maximum Output Current 1A
Range 1A ~ 100uA (6 ranges)
Scan Speed No
USB Compatible No
Power Requirement AC 120V

Potentiostat/ Galvanostat, Compact

SKU: N600-HA151B

Availability: In stock

ASK FOR QUOTE
Add Items to Cart Add To Cart   Add to Quote

Be the first to review this product

Contact our technical department at 518-297-3208 for additional information, a quote, or any technical questions you may have.

Model N600-HA151B is your low-cost and compact Potentiostat solution for fast and convenient field usage. This unit is capable of conducting experiments such as metal testing or metal corrosion monitoring. The adoption of this all-solid-state device results both in stability and portability. The over-current suppression circuit protects the system in case of accidental shorting of the counter or working electrodes. The external control input and potential/current recording output terminals are built-in for immediate data results of the polarization curve when in the field.

Connecting this model to a data logger via the analog port permits the storage of data. We recommend connecting the data logger to your PC via the digital port to retrieve the data and analyzing the results in Excel or your existing software.

As a Potentiostat:
• Maximum output voltage : ±15V
• Maximum output current : ±1A
• Current means. range : ±1A, ±100mA, ±10mA, ±1mA, ±100µA, ±10µA(6 ranges)
• Maximum control potential : ±10V
• Internal setting potential : ±2V
• Internal setting accuracy : 0.5% (setting value) ±3mV
• External control accuracy : < ±3mV
• Response time : < 50µsec
• Reference input resistance : > 10^10 O
• Reference bias current : < 10^-10 A
• Temperature coefficient : 30µV/°C

As a Galvanostat:
• Maximum output current : ±1A,
• Maximum output voltage : ±15V
• Current setting range : ±1A, ±100mA, ±10mA, ±1mA, ±100µA, ±10µA (6 ranges)
• Current setting accuracy : < 1%
• Response time : < 50µsec

As an Electrometer:
• Input resistance : > 10^10 O
• Bias current : < 10^-10 A
• Response time : < 10µ sec
• Conversion accuracy : < ±0.1%
• Potential display range : 10V, 2V

Power requirement :
AC120V, 50-60Hz

Physical dimensions :
220mmx100mmx360mm (WxHxD)

Weight :
7.7kg