Skip to Store Area:

 

http://nadascientific.com/media/catalog/product/cache/7/image/9df78eab33525d08d6e5fb8d27136e95/n/6/n600-ha151b.jpg

Full Size
PDF Downloads Compact Potentiostat/Galvanostat
Dimensions No
Maximum Output Voltage 15V
Maximum Output Current 1A
Range 1A ~ 100uA (6 ranges)
Scan Speed No
USB Compatible No
Power Requirement AC 120V

Potentiostat/ Galvanostat, Compact

SKU: N600-HA151B

Availability: In stock

$4,598.00
Add Items to Cart Add To Cart   Add to Quote

Be the first to review this product

Contact Nouri Dassi at 518-297-3208 for information, quotes, or any questions you may have. For a physical demonstration in your laboratory, please schedule an appointment.


Model N600-HA151B is your low-cost and compact Potentiostat solution for fast and convenient field usage. This unit is capable of conducting experiments such as metal testing or metal corrosion monitoring. The adoption of this all-solid-state device results both in stability and portability. The over-current suppression circuit protects the system in case of accidental shorting of the counter or working electrodes. The external control input and potential/current recording output terminals are built-in for immediate data results of the polarization curve when in the field.


Connecting this model to a data logger via the analog port permits the storage of data. We recommend connecting the data logger to your PC via the digital port to retrieve the data and analyzing the results in Excel or your existing software.


As a Potentiostat:
• Maximum output voltage : ±15V
• Maximum output current : ±1A
• Current means. range : ±1A, ±100mA, ±10mA, ±1mA, ±100µA, ±10µA(6 ranges)
• Maximum control potential : ±10V
• Internal setting potential : ±2V
• Internal setting accuracy : 0.5% (setting value) ±3mV
• External control accuracy : < ±3mV
• Response time : < 50µsec
• Reference input resistance : > 10^10 O
• Reference bias current : < 10^-10 A
• Temperature coefficient : 30µV/°C


As a Galvanostat:
• Maximum output current : ±1A,
• Maximum output voltage : ±15V
• Current setting range : ±1A, ±100mA, ±10mA, ±1mA, ±100µA, ±10µA (6 ranges)
• Current setting accuracy : < 1%
• Response time : < 50µsec


As an Electrometer:
• Input resistance : > 10^10 O
• Bias current : < 10^-10 A
• Response time : < 10µ sec
• Conversion accuracy : < ±0.1%
• Potential display range : 10V, 2V


Power requirement :
AC120V, 50-60Hz


Physical dimensions :
220mmx100mmx360mm (WxHxD)


Weight :
7.7kg

NSTA 1988 St. Louis
NSTA 2013 San Antonio
NSTA 1988 St. Louis
NSTA 1989 Seattle
NSTA 1993 Atlanta
NSTA 2009 New Orleans
NSTA 2009 New Orleans
NSTA 2011 San Francisco
NSTA 2011 San Francisco
NSTA 2011 San Francisco
NSTA 2013 San Antonio